Catalog

Unit of Measure
Items
EB-404 Terminal Block-2

EB-404 Terminal Block

EB-305 Terminal Block

EB-305 Terminal Block

EB-304 Terminal Block

EB-304 Terminal Block

EB-511(A) Terminal Block

EB-511(A) Terminal Block

EB-406 Terminal Block

EB-406 Terminal Block
Underwriters Laboratories (UL) Voltage Rating N/A 300 V
Underwriters Laboratories (UL) Current Rating N/A 75 A N/A 50 A N/A 50 A N/A 120 A N/A 75 A
Canadian Standards Association (CSA) Current Rating N/A 75 A N/A 50 A N/A 50 A N/A 120 A N/A 75 A
Brands N/A Elec-Tron
Number of Tabs N/A 4 x 2 Poles N/A 5 x 2 Poles N/A 4 x 2 Poles N/A 4 x 2 Poles N/A 6 x 2 Poles
Number of Poles N/A 2
Canadian Standards Association (CSA) File N/A 1724185
Underwriters Laboratories (UL) File N/A E61937
Underwriters Laboratories (UL-94) Flammability N/A V1
Underwriters Laboratories (UL) Temperature Rating N/A 150 ºC
Underwriters Laboratories (UL) Wire Size for Torque N/A 2-14 AWG Copper or Aluminum N/A 4-14 AWG Copper or Aluminum N/A 4-14 AWG Copper or Aluminum N/A 1/0-14 AWG Copper or Aluminum N/A 2-14 AWG Copper or Aluminum
Canadian Standards Association (CSA) Voltage Rating N/A 300 V
Canadian Standards Association (CSA) Wire Range N/A 4-14 AWG Copper Only N/A 4-14 AWG Copper Only N/A 4-14 AWG Copper Only N/A 1/0-14 AWG Copper Only N/A 4-14 AWG Copper Only
Wire Size for Torque N/A 10-14 AWG Wire Size for 35 in·lb Torque 2-3 AWG Wire Size for 35 in·lb Torque 4-6 AWG Wire Size for 45 in·lb Torque 8 AWG Wire Size for 40 in·lb Torque N/A 10-14 AWG Wire Size for 20 in·lb Torque 4-6 AWG Wire Size for 35 in·lb Torque 8 AWG Wire Size for 25 in·lb Torque N/A 10-14 AWG Wire Size for 20 in·lb Torque 4-6 AWG Wire Size for 35 in·lb Torque 8 AWG Wire Size for 25 in·lb Torque N/A 1/0-3 AWG Wire Size for 50 in·lb Torque 10-14 AWG Wire Size for 35 in·lb Torque 4-6 AWG Wire Size for 45 in·lb Torque 8 AWG Wire Size for 40 in·lb Torque N/A 10-14 AWG Wire Size for 35 in·lb Torque 2-3 AWG Wire Size for 35 in·lb Torque 4-6 AWG Wire Size for 45 in·lb Torque 8 AWG Wire Size for 40 in·lb Torque
Accessories N/A INS-EB can be added to increase voltage from 300V to 600V
Underwriters Laboratories (UL) 94 Flammability N/A
Underwriters Laboratories (UL) Wire Range N/A
Canadian Standards Association (CSA) Temperature Rating N/A
Underwriters Laboratories (UL) Voltage Rating For Commercial Appliances N/A
Underwriters Laboratories (UL) Tightening Torque for 25 Ampere (A) Current Rating and 10-14 American Wire Gauge (AWG) Copper Only Wire Range N/A
Underwriters Laboratories (UL) Tightening Torque for 50 Ampere (A) Current Rating and 4-6 American Wire Gauge (AWG) Copper or Aluminum Wire Range N/A
Underwriters Laboratories (UL) Tightening Torque for 50 Ampere (A) Current Rating and 8 American Wire Gauge (AWG) Copper or Aluminum Wire Range N/A
Underwriters Laboratories (UL) Tightening Torque for 50 Ampere (A) Current Rating and 10-14 American Wire Gauge (AWG) Copper or Aluminum Wire Range N/A
Canadian Standards Association (CSA) Wire Range for 15 Ampere (A) Current Rating N/A
Canadian Standards Association (CSA) Wire Range for 25 Ampere (A) Current Rating N/A
Canadian Standards Association (CSA) Wire Range for 50 Ampere (A) Current Rating N/A
Underwriters Laboratories (UL) Wire Range (Copper or Aluminum) N/A
Canadian Standards Association (CSA) Wire Range (Copper Only) N/A
Underwriters Laboratories (UL) Copper Wire Range N/A
Underwriters Laboratories (UL) Aluminum Wire Range N/A
Underwriters Laboratories (UL) Tightening Torque N/A
Canadian Standards Association (CSA) Wire Range (Copper or Aluminum) N/A
Canadian Standards Association (CSA) Tightening Torque N/A